2V Flooded Lead-Acid (PzS-PzB) batteries are used for electric forklifts, reach trucks,
order
pickers, pallet trucks, pallet stackers, AGVs shortly all types
of electric forklift applications which requires high level of power, long service life,
maximum
reliability and cyclic endurance.
VT INDUSTRIAL PzS-PzB batteries are recognised as the most cost-effective and well-proven
quality solution at the highest technology integrating the
European harmonization of the DIN and BS ranges which meets the the standards DIN/EN 60254
and
IEC 254-2.
CELL TECHNOLOGY | VLA TUBULAR VENTED |
PLATE TECHNOLOGY | + TUBULAR SPINE PE GAUNTLET, - FLAT GRID |
TERMINALS | BOLT-ON |
GAUNTLET | NON-WOVEN WITH HIGH VOLUME POROSITY |
ELECTROLYTE | 30 °C; 1,29 ± 0,01 kg/l |
LIFE CYCLES | UP TO 1500 @ 80% D.O.D. At 27 - 30 °C |
COMPLIANCES | EN60254-1 & EN60254-2 and IEC254-1 & IEC254-2 |
- 1500 CYCLIC LIFE (WITH REGULAR MAINTENANCE) 80 % DoD.
- 10% MORE CAPACITY WITH THE SAME DIMENSIONS
- AVAILABLE FOR IN-HOUSE SERVICE AND FULLY RECYCLABLE
- FULL COMPLIES WITH IEC 60254-1 STANDARDS
Traction Gel Batteries (PzV) are valve-regulated systems which are specifically developped
for electrical machine charging applications in the
Pharmaceutical, Food, Chemical and similar industries for electric material handling
machines due to the high operational safety, absence of liquid
electrolyte, extreme low emission and high degree of enviromental frendliness of the product
range.
Traction Gel Batteries (PzV) do not require maintenance and can work in below 0 °C
temperature conditions as well.
CELL TECHNOLOGY | VRLA TUBULAR |
PLATE TECHNOLOGY | + TUBULAR SPINE, - FLAT GRID |
TERMINALS | INSULATED BOLT-ON, FM 10 |
ELECTROLYTE | SILICA GEL FORM |
LIFE CYCLES | UP TO 1400+ @ 80% D.O.D. At 27 - 30 °C |
COMPLIANCES | EN60254-1 & EN60254-2 and IEC254-1 & IEC254-2 |
- MAINTENANCE-FREE, EXTREMELY LOW SELF-DISCHARGE
- VERY LOW GASEOUS EMISSIONS DURING OPERATION
- FASTER CHARGING (AVAILABILITY OF 1 BATTERY IN 3 SHIFTS)
- SUITABLE FOR THE PHARMACEUTICAL AND FOOD INDUSTRY
VT INDUSTRIAL SL is one-stop solution partner with all inhouse design, assembly, distribution and after-sales services of Lithium-IonTraction Battery Applications. VT INDUSTRIAL SL Lithium-Ion batteries’ hardware and software design developed to allow for high usage performance, extreme safety and as well as long life expectancy for all material handling applications. VT INDUSTRIAL SL lithium-Ion batteries delivers superior peak power and a fast 1C charge rate and as well as complies with strict test standards and can withstand harsh conditions such as collision, extrusion and acupuncture and fire.
CHEMISTRY | Lithium Iron Phosphate (LiFePO4) |
BMS TECHNOLOGY | VT Industrial Desing, full customisable to meet different needs of the application |
STANDARDIZATION | Standard 24V, 48V and 80V modules compatible with 80% forklift and AWP models. |
OPERATING TEMPERATURE | *Charging (0℃ ~ 50℃), Discharging (-20℃ ~ 55℃)* |
CHARGE TIME / EFFICIENCY | 1-2 Hours / 95% |
SWITCHES | Separate Dual - Power Ports (Charge & Discharge) |
PROTECTION | IP67 protection on cell packs and on batteries (optional) |
LIFE CYCLES | ≥ 3500 Cycle (Capacity ≥ 80% @0.5C Charge - 0.5C Discharge @25±2℃) |
MONITORING | Intelligent 5G or Wi-fi Onboard Monitoring and high precision data collection (optional) |
VT INDUSTRIAL SL Deep Cycle Lead-Acid Battery range is designed for light and semi-traction
applications along with an innovative design compatible
with all universal cyclic applications such as Pallet Trucks, Aerial Work Platforms and
Floor Cleaning Machines.
* EXTREME OPERATIONAL PERFORMANCE
* EASILY TO ACHIEVE 1000 CYCLE LIFE SPAN (IEC 60254)
* LOWEST SELF DISCHARGE AND LOWEST OWNERSHIP COST
* WIDE RANGE OF OPERATING TEMPERATURES
* COMPLETELY RECYCLABLE
TECHNOLOGY | DEEP-CYCLE FLOODED LEAD-ACID |
TERMINAL | UTL, DUAL |
IU CHARGING | “I = min. 12% C5, max. 18% C5 = 2.45 V per cell” |
IUI CHARGING | “I1 = min. 12% C5, max. 18% C5 = 2.4 V per cell I2 = 1.5 % C5 for max. 4 hours |
“LIFE CYCLE | UP TO 1000 cycles (IEC 60254) |
COMPLIANCES | EN60254-1 & EN60254-2 and IEC254-1 & IEC254-2 |
Nominal Voltage | Capacity Ah (C20) | Capacity Ah (C5) | Group Size | Length (mm) | Width (mm) | Height (C) (mm) | Height (D) (mm) | Weight (kg) | Terminal |
---|---|---|---|---|---|---|---|---|---|
6 | 225 | 185 | GC2 | 260 | 180 | 247 | 277 | 28 | UTL |
6 | 315 | 270 | J305 | 308 | 174 | 339 | 365 | 40,5 | DUAL |
6 | 390 | 320 | LI6 | 308 | 174 | 388 | 416 | 48 | DUAL |
8 | 170 | 145 | GC2 | 260 | 180 | 247 | 277 | 29 | UTL |
VT INDUSTRIAL Carbon Nano Tube technology delivers greater charge acceptance and longer life due to irs deep discharge resilience versus conventional lead acid batteries. VT INDUSTRIAL Carbon Nano Flooded Batteries are compatible for deep cycle applications, have ultra energy eciency due to low resistance, suitable for opportunity charging with up to 2 x faster recharge and suitable for extreme temperature variants.
TECHNOLOGY | NANOTUBE CARBON TECHNOLOGY |
TERMINAL | UTL, DUAL |
IU CHARGING | “I1 = min. 12% C5, max. 40% C5 = 2.45 V per cell I2 = 6% C5 for max. 4 hours” |
LIFE CYCLE | UP TO 2 x cyclic life |
COMPLIANCES | EN60254-1 & EN60254-2 and IEC254-1 & IEC254-2 |
Nominal Voltage (V) | Capacity Ah (C20) | Capacity Ah (C5) | Group Size | Length (mm) | Width (mm) | Height (C) (mm) | Height (D) (mm) | Weight (kg) | Terminal |
---|---|---|---|---|---|---|---|---|---|
6 | 225 | 185 | GC2 | 260 | 180 | 247 | 277 | 28 | UTL |
6 | 240 | 195 | GC2 | 260 | 180 | 247 | 277 | 30 | UTL |
6 | 315 | 270 | J305 | 308 | 174 | 339 | 365 | 40.5 | DUAL |
6 | 350 | 295 | J305 | 308 | 174 | 339 | 365 | 44 | DUAL |
6 | 390 | 320 | LI6 | 308 | 174 | 388 | 416 | 48 | DUAL |
6 | 420 | 345 | LI6 | 308 | 174 | 388 | 416 | 50 | DUAL |
8 | 170 | 145 | GC8 | 260 | 180 | 247 | 277 | 29 | UTL |
12 | 150 | 125 | GC12 | 333 | 183 | 248 | 280 | 39 | UTL |
Deep Cycle valve regulated Gel Batteries are preliminary designed for the light traction
market for the golf carts, electrical vehiclers, wheelcharis,
floor cleaning machines and electri working platforms. With an innovative Gel-technology and
maintenance free design, long cycle life and low self
discharge rate Deep Cycle Gel Batteries are compatible with all universal cyclic
applications.
* GOOD HIGH CURRENT PERFORMANCE FOR EXTREME OPERATING CONDITIONS
* 700 CYCLES (DIN EN 60254-1) (IEC 254-1)
* AVAILABLE 45 TO 290 Ah (C₅)
* LOWEST SELF DISCHARGE UP TO 2 YEARS SHELF LIFE
* WIDE RANGE OF OPERATING TEMPERATURES
* COMPLETELY RECYCLABLE
TECHNOLOGY | DEEP-CYCLE FLOODED LEAD-ACID |
TERMINAL | M8 / AP / DU / ST |
IU CHARGING | “I = min. 12% C5, max. 18% C5 = 2.45 V per cell” |
IUI CHARGING | “I1 = min. 12% C5, max. 18% C5 = 2.4 V per cell I2 = 1.5% C5 for max. 4 hours |
LIFE CYCLE | UP TO 700 cycles (IEC 60254) |
COMPLIANCES | EN60254-1 & EN60254-2 and IEC254-1 & IEC254-2 |
Nominal Voltage (V) | Capacity Ah (C20) | Capacity Ah (C5) | Group Size | Length (mm) | Width (mm) | Height (C) (mm) | Weight (kg) | Terminal |
---|---|---|---|---|---|---|---|---|
6 | 210 | 184 | - | 243 | 187 | 274 | 32 | M8 / AP |
6 | 206 | 180 | C2 | 260 | 180 | 258 | 33 | M8 / AP / DU / ST |
6 | 280 | 245 | BCI 305 | 302 | 178 | 345 | 45 | M8 / AP / DU / ST |
6 | 331 | 290 | LI6 | 302 | 178 | 405 | 50 | M10 / AP / DU / ST |
6 | 87 | 46 | CI 34 | 254 | 165 | 175 | 21 | M6 / AP / DU / ST |
12 | 64 | 54 | BCI 34 | 254 | 165 | 211 | 24 | M6 / AP / DU / ST |
12 | 80 | 71 | BCI 24 | 277 | 170 | 215 | 24.5 | M8 / AP / DU / ST |
12 | 87 | 78 | BCI 27 | 306 | 170 | 211 | 32 | M8 / AP / DU / ST |
12 | 105 | 94 | CI 31 | 330 | 172 | 218 | 35 | M8 / AP / DU / ST |
12 | 123 | 108 | BCI 12 / 55HP | 329 | 170 | 240 | 40 | A-POLE |
12 | 123 | 108 | DIN A | 513 | 189 | 215 | 54 | M8 / AP / DU / ST |
12 | 159 | 135 | IN B | 513 | 223 | 215 | 54 | M8 / AP / DU / ST |
12 | 159 | 135 | CI 4D DIN C | 513 | 189 | 215 | 54 | M8 / AP / DU / ST |
12 | 212 | 177 | CI 8D | 518 | 274 | 215 | 68 | M8 / AP / DU / ST |
Valve Regulated Lead-acid batteries in gel form suitable for deep cycle applications and
compatible with all universal cyclic, solar and renewable
applications. For Caravans, Motorhomes, Boats and Maritime leisure applications.
* 100 % MAINTENANCE-FREE
* WIDE RANGE OF CAPACITY BETWEEN 56 to 210 Ah (C20)
* 700 CYCLES @ 80% DOD (DIN EN 60254-1) (IEC 254-1)
* EXCELLENT HIGH-CURRENT PERFORMANCE FOR EXTREME CONDITIONS
* LOW DELF DISCHARGE AND UP TO 2 YEARS SHELF LIFE
* AVAILABLE FOR IN-HOUSE SERVICE AND FULLY RECYCLABLE
TECHNOLOGY | DEEP-CYCLE FLOODED GEL |
TERMINAL | M8 / AP / DU / ST |
IU CHARGING | “I = min. 12% C5, max. 18% C5 = 2.4 V per cell” |
IUI CHARGING | “I1 = min. 12% C5, max. 18% C5 = 2.35 V per cell I2 = 1.5% C5 for max. 4 hours” |
LIFE CYCLES | UP TO 700 cycles (IEC 60254) |
COMPLIANCES | EN60254-1 & EN60254-2 and IEC254-1 & IEC254-2 |
Nominal Voltage | Capacity Ah (C20) | Group Size | Length (mm) | Width (mm) | Height (C) (mm) | Weight (kg) | Terminal | CCA (EN) |
---|---|---|---|---|---|---|---|---|
6 | 206 | GC02 | 260 | 180 | 258 | 33 | M8 / AP / DU / ST | |
12 | 56 | DIN L3 | 277 | 175 | 190 | 21 | A-POLE | 410 |
12 | 81 | DIN L5 | 350 | 175 | 190 | 23 | A-POLE | 540 |
12 | 94 | BCI 31 | 329 | 172 | 205 | 28 | M8 / AP / DU / ST | 460 |
12 | 123 | BCI 12 | 329 | 170 | 258 | 42 | M8 / AP / DU / ST | 750 |
12 | 127 | DIN A | 513 | 189 | 215 | 54 | A-POLE | 540 |
12 | 159 | DIN B | 513 | 223 | 215 | 60 | M8 / AP / DU / ST | 900 |
12 | 159 * | BCI 4D | 513 | 189 | 215 | 54 | M8 / AP / DU / ST | 900 |
12 | 212 | DIN C | 518 | 274 | 215 | 68 | M8 / AP / DU / ST | 1030 |
12 | 212 | BCI 8D | 518 | 274 | 215 | 68 | M8 / AP / DU / ST | 1030 |
Valve Regulated Lead-acid batteries in gel form suitable for deep cycle applications and
compatible with all universal cyclic, solar and renewable
applications. For Caravans, Motorhomes, Boats and Maritime leisure applications.
* 100 % MAINTENANCE-FREE
* WIDE RANGE OF CAPACITY BETWEEN 56 to 210 Ah (C20)
* 700 CYCLES @ 80% DOD (DIN EN 60254-1) (IEC 254-1)
* EXCELLENT HIGH-CURRENT PERFORMANCE FOR EXTREME CONDITIONS
* LOW DELF DISCHARGE AND UP TO 2 YEARS SHELF LIFE
* AVAILABLE FOR IN-HOUSE SERVICE AND FULLY RECYCLABLE
TECHNOLOGY | NANOTUBE CARBON TECHNOLOGY |
TERMINAL | M8 / AP / DU / ST / A POLE |
IU CHARGING | “I = min. 12% C5 max. 30% C5 = 2.4 V per cell” |
IUI CHARGING | “I1 = min. 12% C5 max. 40% C5 = 2.35 V per cell I2 = 1.5 % C5 for max. 4 hours” |
LIFE CYCLE | UP TO 1500 cycles (IEC 60254) |
COMPLIANCES | EN60254-1 & EN60254-2 and IEC254-1 & IEC254-2 |
Nominal Voltage V | M.R.C. 25 Amps | Capacity Ah (C5) | Capacity Ah (C20) | Group Size | Length (mm) | Width (mm) | Height (C) (mm) | Weight (kg) | Terminal |
---|---|---|---|---|---|---|---|---|---|
6 | 435 | 180 | 206 | GC2 | 260 | 180 | 258 | 33 | M8 / AP / DU / ST |
6 | 435 | 184 | 210 | - | 243 | 187 | 274 | 32 | M8 / AP |
6 | 595 | 245 | 280 | BCI 305 | 302 | 178 | 346 | 45 | M8 / AP / DU / ST |
6 | 750 | 290 | 331 | LI6 | 302 | 178 | 405 | 53 | M10 / AP / DU / ST |
12 | 150 | 71 | 80 | BCI 24 | 254 | 168 | 202 | 25 | M6 / AP / DU / ST |
12 | 165 | 78 | 87 | BCI 27 | 306 | 173 | 211 | 32 | M8 / AP / DU / ST |
12 | 170 | 85 | 94 | BCI 31 | 329 | 172 | 205 | 32 | M8 / AP / DU / ST |
12 | 100 | 51 | 56 | BCI 34 | 254 | 168 | 175 | 21 | M6 / AP / DU / ST |
12 | 100 | 75 | 81 | DIN L3 | 277 | 175 | 190 | 21 | A-POLE |
12 | 155 | 73 | 81 | DIN L5 | 350 | 175 | 190 | 28 | A-POLE |
12 | 230 | 108 | 123 | BCI 4D | 513 | 223 | 215 | 54 | M8 / AP / DU / ST |
12 | 430 | 177 | 212 | BCI 8D | 518 | 274 | 215 | 68 | M8 / AP / DU / ST |
12 | 165 | 132 | 159 | Type B | 513 | 223 | 215 | 54 | A-POLE |
12 | 430 | 177 | 212 | Type C | 518 | 274 | 215 | 68 | M8 / AP / DU / ST |
The VT INDUSTRIAL CHARGER range is a complete and versatile range of lead-acid battery chargers for medium and large capacity traction, starting and lifting applications. The conventional battery chargers are designed and constantly updated as per the new technical department in order to guarantee the top performance of our products and to offer the market charging systems capable of preserving lead-acid batteries in the best possible way, ensuring their long life and optimum performance over time.
The VT INDUSTRIAL CHARGER range is a complete and versatile range of lead-acid battery chargers for medium and large capacity traction, starting and lifting applications. The conventional battery chargers are designed and constantly updated as per the new technical department in order to guarantee the top performance of our products and to offer the market charging systems capable of preserving lead-acid batteries in the best possible way, ensuring their long life and optimum performance over time.
V | A | VAC | FAM | 7-8h PB | 10-11-14h PB | 12-14 GEL |
---|---|---|---|---|---|---|
12-24 | 15 | 1X230 | HFY | 92-106 | 127-141-170 | 113-141 |
12-24 | 20 | 1X230 | HFX | 122-141 | 169-188-227 | 151-188 |
12-24 | 30 | 1X230 | HFX | 153-176 | 214-235-283 | 189-226 |
24 | 30 | 1X230 | HFX | 183-212 | 254-282-340 | 226-282 |
24 | 40 | 1X230/110 | HFL | 183-212 | 254-282-340 | 226-282 |
24 | 50 | 1X230/110 | HFL | 244-282 | 339-367-440 | 301-377 |
24 | 15 | 1X230 | HFX | 92-106 | 127-141-170 | 113-141 |
24 | 20 | 1X230 | HFX | 122-141 | 169-188-227 | 151-188 |
36 | 30 | 1X230 | HFZ | 366-423 | 536-564-680 | 452-564 |
36 | 40 | 1X230 | HFZ | 122-141 | 169-188-227 | 151-188 |
48 | 10 | 1X230 | HFZ | 92-106 | 127-141-170 | 113-141 |
48 | 20 | 1X230 | HFZ | 183-212 | 254-282-340 | 226-282 |
48 | 30 | 1X230 | HKL | 468-540 | 677-846-1021 | 577-742 |
48 | 40 | 1X230 | HKP | 381-381 | 457-508-612 | 407-508 |
Validity: 01/05/2024 up to 31/07/2024
Sales terms: in use
V | A | VAC | FAM | VTI CODE REF* | 7-8h PB | 10-11-14h PB | 12-14 GEL |
---|---|---|---|---|---|---|---|
24 | 80 | 3X400 | HFT | HFT 24/80 B | 440-508 | 609-677-816 | 543-677 |
24 | 100 | 3X400 | HFT | HFT 24/100 B | 549-636 | 762-846-1021 | 679-847 |
24 | 120 | 3X400 | HFT | HFT 24/120 B | 659-762 | 914-1015-1224 | 814-1015 |
36 | 80 | 3x400 | HFT | HFT 36/ 80 B | 440-508 | 609-677-816 | 543-677 |
36 | 100 | 3X400 | HFT | HFT 36/100 B | 549-635 | 762-846-1020 | 679-846 |
36 | 120 | 3X400 | HFT | HFT 36/120 B | 659-762 | 914-1015-1224 | 814-1015 |
48 | 80 | 3X400 | HFT | HFT 48/80 B | 440-508 | 609-677-816 | 543-677 |
48 | 100 | 3X400 | HFT | HFT 48/100 B | 549-635 | 762-846-1020 | 679-846 |
48 | 120 | 3X400 | HFT | HFT 48/120 B | 659-762 | 914-1015-1224 | 814-1015 |
72 | 80 | 3X400 | HFT | HFT 72/80 B | 440-508 | 609-677-816 | 543-677 |
72 | 100 | 3X400 | HFT | HFT 72/100 B | 549-635 | 762-846-1020 | 679-846 |
80 | 80 | 3X400 | HFT | HFT 80/80 B | 440-508 | 609-677-816 | 543-677 |
80 | 100 | 3X400 | HFT | HFT 80/100 M B | 549-635 | 762-846-1020 | 679-846 |
96 | 80 | 3X400 | HFT | HFT 96/80 | 440-508 | 609-677-816 | 543-677 |
120 | 60 | 3X400 | HFT | 120/60 | 330-381 | 457-508-612 | 407-508 |
80 | 140 | 3X400 | HFT2 | FT2 80/140 | 769-889 | 1066-1185-1429 | 950-1185 |
80 | 160 | 3X400 | HFT2 | FT2 80/160 | 879-1016 | 1219-1354-1633 | 1086-1354 |
96 | 140 | 3X400 | HFT2 | FT2 96/140 | 769-889 | 1066-1185-1429 | 950-1185 |
120 | 100 | 3X400 | HFT2 | FT2 120/100 | 549-635 | 762-846-1020 | 679-846 |
24 | 140 | 3X400 | HTU | TUC 24/140-8 | 769-889 | 1066-1185-1429 | 950-1185 |
24 | 160 | 3X400 | HTU | TUC 24/160-8 | 879-1016 | 1219-1354-1633 | 1086-1354 |
24 | 180 | 3X400 | HTU | TUC 24/180-8 | 989-1143 | 1371-1523-1837 | 1222-1523 |
24 | 200 | 3X400 | HTU | TUC 24/200-8 | 1099-1270 | 1523-1692-2041 | 1357-1692 |
36 | 140 | 3X400 | HTU | TUC 36/140-8 | 769-889 | 1066-1185-1429 | 950-1185 |
36 | 160 | 3X400 | HTU | TUC 36/160-8 | 879-1016 | 1219-1354-1633 | 1086-1354 |
36 | 180 | 3X400 | HTU | TUC 36/180-8 | 989-1143 | 1371-1523-1837 | 1222-1523 |
36 | 200 | 3X400 | HTU | TUC 36/200-8 | 1099-1270 | 1523-1692-2041 | 1357-1692 |
48 | 140 | 3X400 | HTU | TUC 48/140-8 | 769-889 | 1066-1185-1429 | 950-1185 |
48 | 160 | 3X400 | HTU | TUC 48/160-8 | 879-1016 | 1219-1354-1633 | 1086-1354 |
48 | 180 | 3X400 | HTU | TUC 48/180-8 | 989-1143 | 1371-1523-1837 | 1222-1523 |
48 | 200 | 3X400 | HTU | TUC 48/200-8 | 1099-1270 | 1523-1692-2041 | 1357-1692 |
80 | 120 | 3X400 | HTU | TUC 80/120-8 | 659-762 | 914-1015-1224 | 814-1015 |
24 | 220 | 3X400 | HFT3 | FT3 24/220 | 1209-1397 | 1676-1862-2245 | 1493-1676 |
24 | 240 | 3X400 | HFT3 | FT3 24/240 | 1319-1524 | 1828-2031-2449 | 1629-2031 |
24 | 260 | 3X400 | HFT3 | FT3 24/260 | 1429-1650 | 1980-2200-2653 | 1765-2200 |
24 | 280 | 3X400 | HFT3 | FT3 24/280 | 1538-1777 | 2132-2369-2857 | 1900-2369 |
24 | 300 | 3X400 | HFT3 | FT3 24/300 | 1648-1904 | 2285-2538-3061 | 2036-2538 |
48 | 220 | 3X400 | HFT3 | FT3 48/220 | 1209-1397 | 1676-1862-2245 | 1493-1676 |
48 | 240 | 3X400 | HFT3 | FT3 48/240 | 1319-1524 | 1828-2031-2449 | 1629-2031 |
48 | 260 | 3X400 | HFT3 | FT3 48/260 | 1429-1650 | 1980-2200-2653 | 1765-2200 |
48 | 280 | 3X400 | HFT3 | FT3 48/280 | 1538-1777 | 2132-2369-2857 | 1900-2369 |
48 | 300 | 3X400 | HFT3 | FT3 48/300 | 1648-1904 | 2285-2538-3061 | 2036-2538 |
80 | 180 | 3X400 | HFT3 | FT3 80/180 | 989-1143 | 1371-1523-1837 | 1222-1523 |
80 | 200 | 3X400 | HFT3 | FT3 80/200 | 1099-1270 | 1523-1692-2041 | 1357-1692 |
80 | 220 | 3X400 | HFT3 | FT3 80/220 | 1209-1397 | 1676-1862-2245 | 1493-1676 |
80 | 240 | 3X400 | HFT3 | FT3 80/240 | 1319-1524 | 1828-2031-2449 | 1629-2031 |
80 | 260 | 3X400 | HFT3 | FT3 80/260 | 1429-1650 | 1980-2200-2653 | 1765-2200 |
96 | 160 | 3X400 | HFT3 | FT3 96/160 | 879-1016 | 1219-1354-1633 | 1086-1354 |
96 | 180 | 3X400 | HFT3 | FT3 96/180 | 989-1143 | 1371-1523-1837 | 1222-1523 |
96 | 200 | 3X400 | HFT3 | FT3 96/200 | 1099-1270 | 1523-1692-2041 | 1357-1692 |
120 | 120 | 3X400 | HFT3 | FT3 120/120 | 659-762 | 914-1015-1224 | 814-1015 |
120 | 140 | 3X400 | HFT3 | FT3 120/140 | 769-889 | 1066-1185-1429 | 950-1185 |
120 | 160 | 3X400 | HFT3 | FT3 120/160 | 879-1016 | 1219-1354-1633 | 1086-1354 |
The VT INDUSTRIAL CHARGER range is a complete and versatile range of lead-acid battery chargers for medium and large capacity traction, starting and lifting applications. The conventional battery chargers are designed and constantly updated as per the new technical department in order to guarantee the top performance of our products and to offer the market charging systems capable of preserving lead-acid batteries in the best possible way, ensuring their long life and optimum performance over time.
V | A | VAC | 9h | 12h | 13-14 | CABINET* |
---|---|---|---|---|---|---|
12 | 15 | 1X230 | 77 | 99 | 110 | P5 |
12 | 20 | 1X230 | 103 | 132 | 147 | P5 |
12 | 25 | 1X230 | 128 | 165 | 184 | P5 |
12 | 30 | 1X230 | 154 | 198 | 220 | P5 |
12 | 40 | 1X230 | 206 | 265 | 294 | P5 |
12 | 50 | 1X230 | 257 | 331 | 367 | P6 |
12 | 60 | 1X230 | 308 | 397 | 441 | P6 |
12 | 80 | 1X230 | 411 | 529 | 588 | P6 |
12 | 100 | 1X230 | 514 | 661 | 735 | I2B |
24 | 15 | 1X230 | 77 | 99 | 110 | P5 |
24 | 20 | 1X230 | 103 | 132 | 147 | P5 |
24 | 25 | 1X230 | 128 | 165 | 184 | P5 |
24 | 30 | 1X230 | 154 | 198 | 220 | P5 |
24 | 40 | 1X230 | 206 | 265 | 294 | P5 |
24 | 50 | 1X230 | 257 | 331 | 367 | P6 |
24 | 60 | 1X230 | 308 | 397 | 441 | P6 |
24 | 80 | 1X230 | 411 | 529 | 588 | P6 |
24 | 100 | 1X230 | 514 | 661 | 735 | I2B |
24 | 120 | 1X230 | 617 | 794 | 882 | I2B |
36 | 20 | 1X230 | 103 | 132 | 147 | P5 |
36 | 25 | 1X230 | 128 | 165 | 184 | P5 |
36 | 30 | 1X230 | 154 | 198 | 220 | P6 |
36 | 40 | 1X230 | 206 | 265 | 294 | P6 |
36 | 50 | 1X230 | 257 | 331 | 367 | P6 |
36 | 60 | 1X230 | 308 | 397 | 441 | P6 |
36 | 80 | 1X230 | 411 | 529 | 588 | P6 |
36 | 100 | 1X230 | 514 | 661 | 735 | I2B |
36 | 120 | 1X230 | 617 | 794 | 882 | I2B |
48 | 30 | 1X230 | 154 | 198 | 220 | P6 |
48 | 40 | 1X230 | 206 | 265 | 294 | P6 |
48 | 50 | 1X230 | 257 | 331 | 367 | P6 |
48 | 60 | 1X230 | 308 | 397 | 441 | P6 |
48 | 80 | 1X230 | 411 | 529 | 588 | I1 / I2B |
48 | 100 | 1X230 | 514 | 661 | 735 | I2B |
48 | 120 | 1X230 | 617 | 794 | 882 | I2B |
72 | 60 | 1X230 | 308 | 397 | 441 | I2B |
72 | 80 | 1X230 | 411 | 529 | 588 | I2B |
72 | 100 | 1X230 | 514 | 661 | 735 | I2B |
72 | 120 | 1X230 | 617 | 794 | 882 | I2B |
80 | 60 | 1X230 | 308 | 397 | 441 | I2B |
80 | 80 | 1X230 | 411 | 529 | 588 | I2B |
80 | 100 | 1X230 | 514 | 661 | 735 | I2B |
80 | 120 | 1X230 | 617 | 794 | 882 | I2B |
V | A | VAC | 9h | 12h | 13-14 | CABINET* |
---|---|---|---|---|---|---|
24 | 60 | 3X400 | 308 | 397 | 441 | I1 / I2B |
24 | 80 | 3X400 | 411 | 529 | 588 | I1 / I2B |
24 | 100 | 3X400 | 514 | 661 | 735 | I1 / I2B |
24 | 120 | 3X400 | 617 | 794 | 882 | I1 / I2B |
24 | 140 | 3X400 | 719 | 926 | 1.029 | I1 / I2B |
24 | 160 | 3X400 | 822 | 1.058 | 1.176 | I1 / I2B |
24 | 180 | 3X400 | 925 | 1.190 | 1.322 | I2B |
36 | 60 | 3X400 | 308 | 397 | 441 | I1 / I2B |
36 | 80 | 3X400 | 411 | 529 | 588 | I1 / I2B |
36 | 100 | 3X400 | 514 | 661 | 735 | I1 / I2B |
36 | 120 | 3X400 | 617 | 794 | 882 | I1 / I2B |
36 | 140 | 3X400 | 719 | 926 | 1.029 | I2B |
36 | 160 | 3X400 | 822 | 1.058 | 1.176 | I2B |
36 | 180 | 3X400 | 925 | 1.190 | 1.322 | I2B |
48 | 60 | 3X400 | 308 | 397 | 441 | I1 / I2B |
48 | 80 | 3X400 | 411 | 529 | 588 | I1 / I2B |
48 | 100 | 3X400 | 514 | 661 | 735 | I1 / I2B |
48 | 120 | 3X400 | 617 | 794 | 882 | I1 / I2B |
48 | 140 | 3X400 | 719 | 926 | 1.029 | I2B |
48 | 160 | 3X400 | 822 | 1.058 | 1.176 | I2B |
48 | 180 | 3X400 | 925 | 1.190 | 1.322 | I2B |
72 | 60 | 3X400 | 308 | 397 | 441 | I1 / I2B |
72 | 80 | 3X400 | 411 | 529 | 588 | I1 / I2B |
72 | 100 | 3X400 | 514 | 661 | 735 | I1 / I2B |
72 | 120 | 3X400 | 617 | 794 | 882 | I2B |
72 | 140 | 3X400 | 719 | 926 | 1.029 | I2B |
72 | 160 | 3X400 | 822 | 1.058 | 1.176 | I2B |
72 | 180 | 3X400 | 925 | 1.190 | 1.322 | I3R |
80 | 60 | 3X400 | 308 | 397 | 441 | I1 / I2B |
80 | 80 | 3X400 | 411 | 529 | 588 | I1 / I2B |
80 | 100 | 3X400 | 514 | 661 | 735 | I1 / I2B |
80 | 120 | 3X400 | 617 | 794 | 882 | I2B |
80 | 140 | 3X400 | 719 | 926 | 1.029 | I3R |
80 | 160 | 3X400 | 822 | 1.058 | 1.176 | I3R |
80 | 180 | 3X400 | 925 | 1.190 | 1.322 | I3R |
96 | 60 | 3X400 | 308 | 397 | 441 | I1 / I2B |
96 | 80 | 3X400 | 411 | 529 | 588 | I1 / I2B |
96 | 100 | 3X400 | 514 | 661 | 735 | I2B |
96 | 120 | 3X400 | 617 | 794 | 882 | I2B |
96 | 140 | 3X400 | 719 | 926 | 1.029 | I3R |
96 | 160 | 3X400 | 822 | 1.058 | 1.176 | I3R |